Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 24.5W @15Min-rate to 1.67V per cell @ 25°C (77°F)
Weight Approx. 1.84 Kg (4.06 lbs)
Maximum Discharge current 100/130A (5 Sec)
Internal Resistance Approx. 25.8 mΩ
Operating Temperature Range Discharge:-15℃~50℃(5°F~122°F)
Charge:-15℃~40℃(5°F~104°F)
Storage:-15℃~40℃(5°F~104°F)
Nominal Operating Temperature Range 25℃±3℃(77°F±5°F)
Float charging voltage 13.5 to 13.8 VDC/Unit Average at 25℃ (77°F)
Recommended Maximum Charging current limit 2.5A
Equalization and Cycle Service 14.4 to 15.0 VDC/Unit Average at 25℃(77°F)
Self Discharge It should be more than 75% of the capacity before storage after stocked for 6 months at ambient temp. 25℃
Terminal F1/F2-Faston Tab187/250
Container Material ABS(UL94-HB) & Flame retardant(UL94-V0) available upon request.