IEEE Standard | IEEE 802.3 10Base-T Ethernet | ||
IEEE 802.3u 100Base-TX Fast Ethernet | |||
IEEE 802.3ab 1000Base-T Gigabit Ethernet | |||
IEEE 802.3z 1000Base-X Gigabit Ethernet | |||
IEEE 802.3x Flow Control and Back Pressure | |||
IEEE 802.3af PoE (Power over Ethernet) | |||
IEEE 802.3at PoE+ (Power over Ethernetenhancements) | |||
Data Processing | Store and Forward | ||
Flow Control | IEEE 802.3x flow control, back pressure flow control | ||
Provides Broadcast Storm Protection |
Present, Enable / Disable set by DIP SW | ||
Jumbo Frame | 10K Bytes | ||
MAC Address Table | 8K | ||
Packet Buffer Size | 1Mbits | ||
PoE standard | IEEE 802.3at/af | ||
PoE RJ-45 pin Assignment |
RJ-45 port # 1~# 4 support IEEE 802.3at/af End- Span, Alternative A mode |
||
Positive (V+): RJ-45 pin 1, 2. | |||
Negative (V-): RJ-45 pin 3, 6. | |||
Data (1, 2, 3, 6, 4, 5, 7, 8 ) | |||
Network Connector | 4 x RJ-45 (IGS-402S-4PH24, 6 x RJ-45 (IGS-600-4PH24) 10/100/1000Base-T auto negotiation speed, Auto MDI/MDI-X function, Full/Half duplex |
||
2x 100/1000Base-X SFP (IGS-402S-4PH24) 2x1000Base-X Fiber connector: SC Muti Mode |
|||
Network Cable | UTP/STP above Cat. 5e cable | ||
EIA/TIA-568 100-ohm (100m) | |||
Fiber Cable (Multi-mode): 50/125um, 62.5/125um Fiber Cable (Single-mode): 9/125um |
|||
Protocols | CSMA/CD | ||
LED | Per unit: Power 1 (Green), Power 2 (Green), Fault (Amber) | ||
LED | Per RJ-45 port : Link/Active (Green), Speed 10 (OFF ), 100 (Green), 1000 (Yellow) |
||
Fiber Per port: Link/Active (Green) | |||
Per Port PoE LED • Active : ON • Inactive : OFF • Fault : Flash (Fault: Over Load, Short Circuit, Port failed at Startup) |
|||
DIP SW | DIP 1 | ON : Disable power failure alarm OFF : Enable power failure alarm |
|
DIP 2 | ON : Disables broadcast storm protection OFF : Enable broadcast storm protection |
||
DIP 3 | ON : Fiber 2 for 100Base-FX SFP OFF : Fiber 2 for Gigabit SFP (Only for IGS-402S-4PH24) |
||
DIP 4 | ON : Fiber 1 for 100Base-FX SFP OFF : Fiber 1 for Gigabit SFP (Only for IGS-402S-4PH24) |
||
Reserve Polarity Protection |
Present | ||
Overload Current Protection |
Present | ||
Power Supply | Redundant Dual DC 24/48V (20~57VDC) Input power (Removable Terminal Block) Built-in very high efficiency booster(94~97%) to rise up 55 VDC for PoE output Regulate PoE output voltage (55VDC) to stabilize PoE device, and guarantee delivery PoE power distance to 100meter (Figure 2) |
||
Power Consumption | Input Voltage |
IGS-402S- 4PH24 |
IGS-600- 4PH24 |
24VDC | 143.3W | 142.9W | |
48VDC | 138.2W | 139.6W | |
PoE Power Output | Maximum PoE Output power budget 120W (30W/Per Port) | ||
Alarm Relay Contact | Relay outputs with current carrying capacity of 1A @24VDC | ||
Removable Terminal Block | Provides 2 Redundant power, Alarm relay contact, 6 Pin | ||
Operating Temperature |
-10 ~ 60°C (IGS-402S-4PH24, IGS-600-4PH24) |
||
-40 ~ 75°C (IGS-402S-4PHE24, IGS-600-4PHE24) | |||
Operating Humidity | 5% to 95% (Non-condensing) | ||
Storage Temperature | -40 ~ 85°C | ||
Housing | Rugged metal, IP30 Protection and fanless | ||
Dimensions | 106 x 62.5 x 134.8mm (D X W X H) | ||
Weight | 0.84kg (IGS-402S-4PH24) 0.84kg (IGS-600-4PH24) |
||
Installation Mounting | DIN Rail mounting or wall mounting | ||
MTBF | 736,988 Hours @25°C (IGS-402S-4PH24) 649,579 Hours @25°C (IGS-600-4PH24) (MIL-HDBK-217) |
||
Warranty | 5 years | ||
Certification | |||
EMC | CE | ||
EMI (Electromagnetic Interference) | FCC Part 15 Subpart B Class A,CE EN55022 Class A | ||
Railway | Traffic EN50121-4 | ||
Immunity for Heavy Industrial Environment | EN61000-6-2 | ||
Emission for Heavy Industrial Environment | EN61000-6-4 | ||
EMS (Electromagnetic Susceptibility) Protection Level |
EN61000-4-2 (ESD) Level 3, Criteria B | ||
EN61000-4-3 (RS) Level 3, Criteria A | |||
EN61000-4-4 (Burst) Level 3, Criteria A | |||
EN61000-4-5 (Surge) Level 3, Criteria B | |||
EN61000-4-6 (CS) Level 3, Criteria A | |||
EN61000-4-8 (PFMF, Magnetic Field) Field Strength: | |||
300A/m, Criteria A | |||
Safety | UL60950-1 | ||
Shock | IEC 60068-2-27 | ||
Freefall | IEC 60068-2-32 | ||
Vibration | IEC 60068-2-6 |